Electric drives powered by 24V DC

Control of valves in systems with renewable power sources. Direct connection to an energy storage system without additional converters.

Fill in the questionnaire
Electric drives powered by 24V DC
Characteristics

Purpose: 

Explosion-proof intelligent electric drive for controlling any type of pipeline fittings in systems with renewable power sources (RES) and a supply voltage of 24 V DC.

Functions: 

• Built-in electronic limit and torque switches 
• Built-in frequency converter for motion control
• Reliable mechanical transmissions
• Function of bringing to a safe position;
• Analog and discrete control;
• Management and configuration via interface;
• Intelligent monitoring and protection system;
• Volatile electronic position sensor;
• Configuration without opening the shell;
• Double insulation of the connection box;
• No mechanical contacts.

Features and Benefits:

• High operating efficiency due to frequency control of the electric motor
• Application of synchronous electric motors with permanent magnets
• Drive energy efficiency due to highly efficient gears
• Wide range of supply voltages
• Function for limiting power consumption from the power supply
• Remote configuration and monitoring technologies (DTM)
• Availability of built-in WIFI interface; ready for the Digital Economy, Industry 4.0 Ready;
• Possibility of position control at low speed and quick cut-off based on a safety signal;
• Compact size and monoblock design of the electric motor and control electronic unit;
• Highly reliable cycloidal gears and gears with intermediate rolling elements, ball screws;
• High reliability and fault tolerance;
• Self-diagnosis, built-in archiving of emergency events
• Partial valve stroke test (PST-test);
• Compliance with functional safety standards according to GOST R IEC 61508 and GOST R IEC 61511 at the SIL2 level.

Specifications:

Type linear, part-turn
Valves to be automated
for all types
Valve diameter DN 15 - 700 mm
Version explosion proof 1 Ex d IIB T4 Gb Х
Torque 40 – 90000 Nm
3500 – 220000 N
Supply voltage 24 V DC (range from 12 V to 36 V)
Operating temperature
from -63 to +50 °С 
Time ready to be fired at the security
features after power-up
5 min
Integration into the automated
process control system
Digital inputs, outputs, RS-485
interface (Modbus RTU), analog control
and feedback signals
Supports DTM and remote
configuration and monitoring technology
Yes


Modifications
   
Electric drive type
MAX torque, Nm
Shutdown torque setting range, Nm
Max speed at the gearbox output, rev/min
Mode s2, min Mode s3,
OD%; Tc min
Mode s4, p/h Seat type
RemTEK.M.40.50

40

   

8...40

   

50

30

25%, 60min

1200

А

   
RemTEK.M.40.70

70

30

25%, 60min

1200

RemTEK.M.40.110

110

30

25%, 60min

1200

RemTEK.M.60.80

60

 

12...60

 

80

30

25%, 60min

1200

А

 
RemTEK.M.60.100

100

30

25%, 60min

1200

RemTEK.M.70.40

70

    

14...70

40

30

25%, 60min

1200

А

 
RemTEK.M.70.70

70

30

25%, 60min

1200

RemTEK.M.100.45

100

20...100

45

30

25%, 60min

1200

А(B)

RemTEK.M.120.50

120

24...120

50

30

25%, 60min

1200

А(B)

RemTEK.M.150.30

150

 

30...150

 
30

30

25%, 60min

1200

А(B)

 
RemTEK.M.150.50

50

30

25%, 60min

1200

RemTEK.M.200.20

200

 

40...200

 

20

30

25%, 60min

1200

А(B)

 
RemTEK.M.200.30

30

30

25%, 60min

1200

RemTEK.M.250.230

250

50...250

230

30

25%, 60min

1200

B

RemTEK.M.300.12

300

60..300

12

30

25%, 60min

1200

B

RemTEK.M.600.6

600

120..600

6

30

25%, 60min

1200

B(C)

RemTEK.M.1000.3

1000

200..1000

3

30

25%, 60min

1200

B(C)

Electric drive type

MAX torque, Nm

Shutdown torque setting range, Nm

Minimum working stroke time, s

Mode s2, min

Mode s3,
OD%; Tc min

Mode s4, p/h    

Seat type

RemTEK.P.64

64

12,8..64

1

30

25%, 60min

1200

F07

RemTEK.P.125

125

25...125

0,4; 3; 4; 6

30

25%, 60min

1200

F07

RemTEK.P.250

250

50..250

1; 3; 4; 6

30

25%, 60min

1200

F07

RemTEK.P.600

600

120..600

2; 4; 6

15

25%, 60min

1200

F10

RemTEK.P.1000

1000

200..1000

3; 6

30

25%, 60min

1200

F12

RemTEK.P.2000

2000

400..2000

8; 12

30

25%, 60min

1200

F14

RemTEK.P.4000

4000

800...4000

16; 24

30

25%, 60min

1200

F16

RemTEK.P.8500

8500

1700...8500

32; 60

30

25%, 60min

600

F25

RemTEK.P.10000

10000

2000...10000

36; 60

30

25%, 60min

600

F25

RemTEK.P.16000

16000

8000...16000

30; 50; 60

30

25%, 60min

600

F30

RemTEK.P.24000

24000

4800..24000

65

30

25%, 60min

600

F30

Electric drive type

MAX moment, Н

Trip force setting range, Н

Maximum output speed of the gearbox, mm/s

Full speed ahead, mm

Mode s2, min

Mode s3,
OD%; Tc min

Mode s4, p/h

RemTEK.L.3500

3500

700..3500

4; 7; 35

60

30

25%, 60min

1200

RemTEK.L.7000

7000

1400..7000

4; 7; 15; 35

60/100/125/160/200

30

25%, 60min

1200

RemTEK.L.10000

10000

2000..10000

7; 10; 15; 20; 35

60/100/125/160/200

30

25%, 60min

1200

RemTEK.L.18000

18000

3600..18000

4; 7; 10; 12; 20; 25

60/100/125/160/200

30

25%, 60min

1200

RemTEK.L.25000

25000

5000..25000

6; 10

60/100/125/160/200

30

25%, 60min

1200

RemTEK.L.30000

30000

6000..30000

10

125/160/200

30

25%, 60min

1200

RemTEK.L.45000

45000

9000..45000

5

100/150/220

30

25%, 60min

1200

RemTEK.L.65000

65000

13000..65000

5

100/150/220

30

25%, 60min

1200