Compact electric actuators
High-precision, energy-efficient, small-sized electric actuator for controlling all types of valves as part of technological installations.
Fill in the questionnaire
Designation:
Electric drives are used to regulate and cut off flows in modular equipment and in process plants at oil and gas facilities.
The compact design provides a number of advantages in the design of process units.
Electric drives are used in explosive zones of class 1 and 2 in accordance with GOST R 60079 (in explosive zones of all classes), where may be formed vapor- and gas-and-air explosive mixtures of IIA and IIB groups T1, T2, T3, T4 as per the classification of GOST R IEC 60079-20-1.
RemTEK is used in ESD systems, safety circuits (SIL2) to control isolation shut-off or control pipeline valves.
Functions:
- Electronic limit and torque switches;
- In-built frequency converter for motion control;
- Reliable mechanical gears;
- Bringing to a safe position function;
- Analogue and discrete control;
- Control and setting via interfaces;
- Intelligent monitoring and protection systems;
- Absolute electronic position sensor;
- Nonintrusive set up;
- No mechanical contact.
Features and Benefits:
- High-efficient self-controlled synchronous electric motor with permanent magnets;
- In-built frequency converter;
- Cycloidal gearboxes and gearboxes with intermediate rolling elements;
- Universal control unit for all modifications of electric drives;
- Increased resource;
- High reliability and fail safety;
- Self-diagnosis, built-in archiving of emergency events;
- Embodiments provided with safe state function (NO/NC) with built-in energy storage on supercapacitors;
- Supply voltage: 230 V or 400 V;
- Partial valve stroke test (PST-test);
- Functional safety SIL2;
- In-built WIFI interface;
- Ready to “Digital Economy”, “Industry 4.0 Ready”;
- Double insulated connection box;
-
Compliance with the requirements of STO GAZPROM 2-4.1-212-2008 for the time of overlapping ball valves.
Type |
linear, part-turn, multi-turn | |
Valves to be automated |
for all types |
|
Valve diameter |
DN 15 - 500 mm |
|
Version |
explosion proof 1ExdIIBT4 Х | |
Torque |
40 – 10000 Nm 1000 – 25000 N |
|
Rotation speed |
0,6 – 9 rev/min | |
Supply voltage |
400 V AC or 230 V AC |
- Part-turn Drives
- Linear Drives
- Multi-turn Drives
Modifications |
Torque limitation range, Nm | Shut off time, sec | |||
RemTEK.P.75
|
15...75 |
6...60 |
|||
RemTEK.P.125
|
30...125 |
||||
RemTEK.P.250
|
50...250 |
||||
RemTEK.P.600
|
120...600 |
||||
RemTEK.P.1000
|
200...1000 |
||||
RemTEK.P.2000
|
400...2000 |
9...100 |
|||
RemTEK.P.4000
|
800...4000 |
||||
RemTEK.P.8500
|
1700...8500 |
12...100 |
|||
RemTEK.P.10000
|
2000...10000 |
Modifications |
Torque limitation range, N |
Speed at gearbox output, mm/sec |
|||
RemTEK.L.3500
|
700...3500 |
1...20 |
|||
RemTEK.L.7000
|
1400...7000 |
||||
RemTEK.L.10000
|
2000...10000 |
||||
RemTEK.L.18000
|
3600...18000 |
||||
RemTEK.L.25000
|
5000...25000 |
||||
RemTEK.L.30000
|
6000...30000 |
||||
RemTEK.L.45000
|
9000...45000 |
||||
RemTEK.L.65000
|
18000...65000 |
Modifications |
Torque limitation range, Nm | Rotation speed of output arm, rev/min | |||
RemTEK.M.50
|
10...50 |
5...150 |
|||
RemTEK.M.100
|
20...100 |
||||
RemTEK.M.150
|
30...150 |
||||
RemTEK.M.200
|
40...200 |
4...80 |
|||
RemTEK.M.300
|
60...300 |
3...60 |
|||
RemTEK.M.600
|
120...600 |
3...30 |
|||
RemTEK.M.1000
|
200...1000 |
1...20 |